When it comes to wiring a garage, there are several considerations to make, from ensuring the proper placement of outlets to choosing the best type of receptacles. One of the questions that often arises in this context is whether or not it’s advisable to use surface mount receptacles in a garage. These types of outlets, typically mounted on the surface of walls rather than embedded within them, are becoming increasingly popular for various applications, particularly in areas where traditional electrical installation methods might be impractical or undesirable. Let’s go over can you use surface mount receptacles for outlets in garage.
In this article, we’ll dive into the specifics of surface mount receptacles, explore their pros and cons, and answer the key question of whether or not they are suitable for use in a garage. We’ll also look at the key considerations for wiring outlets in a garage, potential safety concerns, and the regulations that govern electrical installations.

What Are Surface Mount Receptacles?
Surface mount receptacles are electrical outlets that are mounted on the surface of the wall rather than being recessed into the wall cavity. These receptacles are typically housed in surface-mounted boxes or enclosures, which are installed directly on the exterior of the drywall or other wall material. Unlike traditional outlets, which are flush with the wall, surface-mounted outlets often protrude slightly and are visible.
These types of receptacles are most commonly used in situations where you either want to avoid cutting holes in the wall or when it is impractical to run wires through the wall due to obstacles or existing construction. Surface mount receptacles are available in various types, including both single and multiple outlets, and can be installed in both residential and commercial settings.

Why Use Surface Mount Receptacles?
Surface mount receptacles offer several advantages over traditional outlets that are recessed into the wall. The most common reasons why people choose surface mount outlets include:
- Ease of Installation: Installing a surface mount receptacle is generally quicker and easier than installing a recessed one, especially in garages or areas with concrete walls where it might be difficult to cut into the wall.
- Flexibility: These outlets can be relocated or adjusted more easily than traditional outlets. If you need to move the outlet later on, you can simply detach the surface-mounted box and reposition it.
- Cost-Effective: Surface mount receptacles tend to be more affordable than recessed outlets because they don’t require as much labor or materials to install.
- Accessibility: Since surface mount receptacles are installed on the surface of the wall, they are easier to access for maintenance or upgrades. There’s no need to cut open walls to replace an old or malfunctioning outlet.
- Aesthetics: Although they may not always be as sleek as traditional outlets, surface mount receptacles can be designed to blend in with various interior styles. Some homeowners opt for decorative surface-mounting boxes that can complement their decor.
Given these benefits, many homeowners and builders choose surface mount receptacles for garage installations, especially in areas where the wiring needs to be easily accessible or when traditional methods are difficult or cost-prohibitive.

Are Surface Mount Receptacles Safe for Garages?
One of the main concerns people have when installing surface mount receptacles is whether or not they are safe for use in specific environments such as garages. While surface mount receptacles can be a safe and effective option, certain considerations must be made to ensure they meet safety standards, especially in garages, where there are additional hazards to consider.
Electrical Code Compliance
Before you decide to install surface mount receptacles in your garage, it’s important to familiarize yourself with local electrical codes and regulations. In the United States, the National Electrical Code (NEC) governs most aspects of electrical installation, and it sets specific guidelines for the installation of electrical outlets in various environments.
In a garage, the NEC typically requires that outlets be installed at a certain height from the floor (typically 18 inches) and that they be placed away from potential sources of moisture, such as water pipes, or in areas prone to splashing, like near utility sinks. While surface mount receptacles themselves are generally allowed, you will still need to ensure that the installation complies with these other regulations.
Environmental Hazards
Garages often have unique environmental conditions that can affect electrical installations, including high levels of moisture, dirt, and dust. These factors can increase the risk of electrical failure or fire if the installation isn’t done properly. Surface mount receptacles may be more exposed to these elements, which could lead to issues like corrosion or dust buildup in the outlet box.
To mitigate these risks, consider using receptacles with weather-resistant covers or enclosures that can protect the electrical components from dust, debris, and moisture. You should also ensure that the wiring and electrical connections are properly insulated and protected to prevent accidental contact with water or metal surfaces.
Shock Prevention
Since surface mount receptacles sit on the surface of the wall, there’s a greater chance that they could be exposed to physical damage or tampering. In a garage, tools, machinery, or vehicles could inadvertently come into contact with the receptacle, leading to a potential risk of electric shock or short circuits. To minimize this risk, choose receptacles that are enclosed in sturdy, durable boxes and consider placing them in locations that are less likely to be accidentally struck.

Can Surface Mount Receptacles Be Used for Outdoor Garages?
In some cases, people build garages that are partially or completely exposed to the outdoors, such as in carports or garages with roll-up doors. These environments pose a unique set of challenges when it comes to electrical safety, and surface mount receptacles can still be used in these situations—but additional precautions should be taken.
When using surface mount receptacles in outdoor environments, it is crucial to choose receptacles and enclosures that are rated for outdoor use. This means they should be waterproof and resistant to the elements. Additionally, all wiring should be rated for outdoor use and installed with proper weatherproofing materials, such as conduit, which provides an added layer of protection.
Weatherproof Boxes and Covers
To further protect your surface mount receptacles, you should use weatherproof boxes and covers. These covers are designed to shield the outlet from the elements, preventing rain, snow, or debris from causing damage or electrical issues. Installing weatherproof covers is especially important in outdoor garages or any other area subject to harsh weather conditions.
Proper Grounding
Grounding is a crucial part of electrical safety. Ensure that the surface mount receptacle is properly grounded according to NEC guidelines. This helps to protect against electrical surges and prevents shocks or fires that may occur in the event of a malfunction.

Final Thoughts: Are Surface Mount Receptacles Right for Your Garage?
In summary, surface mount receptacles can be a great option for outlets in your garage. They are easy to install, flexible, and cost-effective. However, they do require careful consideration to ensure that they are safe and compliant with electrical codes. While they are generally safe when installed properly, it’s important to use weather-resistant or durable boxes, ensure proper grounding, and protect the receptacles from environmental hazards in your garage.
Always check with local building codes and electrical regulations to ensure that you are following the proper procedures for installing electrical outlets. If in doubt, it’s a good idea to consult with a licensed electrician to ensure that your garage outlet installations meet the necessary safety standards. With the right precautions, surface mount receptacles can provide a reliable and convenient solution for your garage’s electrical needs.
If you’re looking for quality structures to house your electrical installations or to create the perfect space for your family, Ohio Cabins & Structures provides custom cabins, homes, and garages to meet your unique needs. We can help you create a comfortable, functional space with the best possible building materials and designs to suit your lifestyle. We hope this helps you understand can you use surface mount receptacles for outlets in garage.